Skip to content
Serving Montana, Northern Idaho & Southern Alberta
Septic & Wastewater NPCA certified
On-site wastewater

Septic & Wastewater

NPCA-certified septic tanks, pump and dosing chambers, interceptors, and advanced treatment systems from 500 to 10,000 gallons — for single homes, commercial sites, and everything between.

500–10,000 gal
Capacity range
1 or 2
Compartments
On our fleet
Delivered & set
Overview

Tanks, chambers & treatment sized for the job.

NPCA-certified septic tanks, pump and dosing chambers, interceptors, and advanced treatment systems from 500 to 10,000 gallons — for single homes, commercial sites, and everything between.

Single- and two-compartment configurations
Gravity, siphon, or pump-dosed systems
Any tank can be built traffic-rated to HS-20
Concrete, PVC, or fiberglass risers & lids
Delivered and set on grade by our own fleet
NPCA-certified production & QC
Sizes & specs

Filter to your size

Filter by how the product will be used, search by size, and pull the drawing you need — no scrolling through an accordion.

28 products

Sizes and specifications for Septic & Wastewater
Product Comp.Dimensions (L×W×H)LoadDrawing
500 Gallon Septic / Pump Chamber500 gal16'8" × 4'4" × 4'10" H-10 500 Gallon ADV Tank Drawing v5 PDF — drawing for 500 Gallon Septic / Pump Chamber, opens in a new tab
1000 Gallon Septic / Pump Chamber1,000 gal29'2" × 5'2" × 5'6" H-10 / H-20 opt. 1000 Gallon Septic Drawing V4 — drawing for 1000 Gallon Septic / Pump Chamber, opens in a new tab 1000 Gallon Advantex Drawing V5 — drawing for 1000 Gallon Septic / Pump Chamber, opens in a new tab
1000/500 Gallon Septic / Pump Chamber1,000 gal 1000/500 Gallon Septic Pump Chamber — drawing for 1000/500 Gallon Septic / Pump Chamber, opens in a new tab
1000 / 500 Septic / Pump Chamber1,500 gal212'0" × 5'2" × 5'6" H-10 / H-20 opt.
1500/500 Gallon Septic / Pump Chamber1,500 gal 1500/500 Gallon Septic Pump Chamber — drawing for 1500/500 Gallon Septic / Pump Chamber, opens in a new tab
1500 / 500 Septic / Pump Chamber2,000 gal213'6" × 5'6" × 5'8" H-20 opt.
2500 Gallon 1650/850 Septic / Pump Chamber2,500 gal215'0" × 5'8" × 5'10" H-20 opt. 1667 Septic – 832 Pump Chamber — drawing for 2500 Gallon 1650/850 Septic / Pump Chamber, opens in a new tab
2000/1000 Gallon Septic / Pump Chamber2,000 gal 2000/1000 Septic Pump Chamber — drawing for 2000/1000 Gallon Septic / Pump Chamber, opens in a new tab
2000 / 1000 Septic / Pump Chamber3,000 gal217'2" × 5'10" × 6'0" H-20 opt.
1000/500 Siphon Tank1,000 gal212'0" × 5'2" × 5'6" H-10 1000/500 Gallon Siphon Chamber 316 — drawing for 1000/500 Siphon Tank, opens in a new tab 1000/500 Gallon Siphon Chamber 417 — drawing for 1000/500 Siphon Tank, opens in a new tab
1500/500 Siphon Tank1,500 gal213'6" × 5'6" × 5'8" H-10 1500/500 Gallon Siphon Chamber 316 — drawing for 1500/500 Siphon Tank, opens in a new tab 1500/500 Gallon Siphon Chamber 417 — drawing for 1500/500 Siphon Tank, opens in a new tab
1500 Gallon Septic1,500 gal111'0" × 5'6" × 5'6" H-10 1500 Gallon Septic Tank v2 — drawing for 1500 Gallon Septic, opens in a new tab 1500 Advantex Drawing V2 — drawing for 1500 Gallon Septic, opens in a new tab
1500 Gallon Low Profile Septic Tank1,500 gal 1500 Low Profile Septic — drawing for 1500 Gallon Low Profile Septic Tank, opens in a new tab
1500 Gallon Low-Profile Septic1,500 gal113'0" × 6'0" × 4'6" H-10
2000 Gallon Septic2,000 gal113'6" × 5'8" × 5'8" H-20 opt.
2000 Gallon Septic Tank2,000 gal 2000 Advantex Drawing V4 — drawing for 2000 Gallon Septic Tank, opens in a new tab
2500 Gallon Septic2,500 gal115'0" × 5'10" × 5'10" H-20 opt.
2500 Gallon Septic Tank2,500 gal 2500 Septic Drawing V2 — drawing for 2500 Gallon Septic Tank, opens in a new tab 2500 Advantex Drawing V5 — drawing for 2500 Gallon Septic Tank, opens in a new tab
6000 Gallon Septic6,000 gal222'0" × 6'6" × 6'6" H-20
6000 Gallon Septic Tank6,000 gal 6000 Septic Drawing V2 — drawing for 6000 Gallon Septic Tank, opens in a new tab
1000 Gallon Interceptor / Separator1,000 gal29'2" × 5'2" × 5'6" H-20 opt.
1000 Gallon Interceptor / Separator Tank1,000 gal 1000 Gallon Grease Interceptor v5 — drawing for 1000 Gallon Interceptor / Separator Tank, opens in a new tab 1000 Gallon Sand Oil Separator Drawing v1 — drawing for 1000 Gallon Interceptor / Separator Tank, opens in a new tab
1500 Gallon Interceptor / Separator1,500 gal211'0" × 5'6" × 5'6" H-20 opt.
1500 Gallon Interceptor / Separator Tank1,500 gal 1500 Sand Oil Separator Drawing V4 — drawing for 1500 Gallon Interceptor / Separator Tank, opens in a new tab DOL 1500 — drawing for 1500 Gallon Interceptor / Separator Tank, opens in a new tab
2000 Gallon Interceptor / Separator2,000 gal313'6" × 5'8" × 5'8" H-20 opt.
2000 Gallon Interceptor / Separator Tank2,000 gal 2000 Grease Interceptor Drawing – COK v7 — drawing for 2000 Gallon Interceptor / Separator Tank, opens in a new tab 2000 Sand Oil Interceptor Drawing v5 — drawing for 2000 Gallon Interceptor / Separator Tank, opens in a new tab
AdvanTex Level 2 Treatment System2System — varies H-10 ATX – 20 — drawing for AdvanTex Level 2 Treatment System, opens in a new tab ATX – 100 — drawing for AdvanTex Level 2 Treatment System, opens in a new tab ATX – MAX — drawing for AdvanTex Level 2 Treatment System, opens in a new tab
Pump Station Package16'8" × 4'4" × 5'10" H-10 / H-20 opt. Grinder Solids Pump Package — drawing for Pump Station Package, opens in a new tab

500 Gallon Septic / Pump Chamber

500 gal
Pump & dosing Residential
Compartments
1
Dimensions
6'8" × 4'4" × 4'10"
Load rating
H-10

1000 Gallon Septic / Pump Chamber

1,000 gal
Pump & dosing Residential
Compartments
2
Dimensions
9'2" × 5'2" × 5'6"
Load rating
H-10 / H-20 opt.

1000/500 Gallon Septic / Pump Chamber

1,000 gal
Pump & dosing Residential

1000 / 500 Septic / Pump Chamber

1,500 gal
Pump & dosing Residential
Compartments
2
Dimensions
12'0" × 5'2" × 5'6"
Load rating
H-10 / H-20 opt.

1500/500 Gallon Septic / Pump Chamber

1,500 gal
Pump & dosing Residential

1500 / 500 Septic / Pump Chamber

2,000 gal
Commercial Pump & dosing Residential
Compartments
2
Dimensions
13'6" × 5'6" × 5'8"
Load rating
H-20 opt.

2500 Gallon 1650/850 Septic / Pump Chamber

2,500 gal
Commercial Pump & dosing Residential
Compartments
2
Dimensions
15'0" × 5'8" × 5'10"
Load rating
H-20 opt.

2000/1000 Gallon Septic / Pump Chamber

2,000 gal
Pump & dosing Residential

2000 / 1000 Septic / Pump Chamber

3,000 gal
Commercial Pump & dosing
Compartments
2
Dimensions
17'2" × 5'10" × 6'0"
Load rating
H-20 opt.

1000/500 Siphon Tank

1,000 gal
Siphon
Compartments
2
Dimensions
12'0" × 5'2" × 5'6"
Load rating
H-10

1500/500 Siphon Tank

1,500 gal
Siphon
Compartments
2
Dimensions
13'6" × 5'6" × 5'8"
Load rating
H-10

1500 Gallon Septic

1,500 gal
Residential
Compartments
1
Dimensions
11'0" × 5'6" × 5'6"
Load rating
H-10

1500 Gallon Low Profile Septic Tank

1,500 gal
Residential

1500 Gallon Low-Profile Septic

1,500 gal
Residential
Compartments
1
Dimensions
13'0" × 6'0" × 4'6"
Load rating
H-10

2000 Gallon Septic

2,000 gal
Commercial Residential
Compartments
1
Dimensions
13'6" × 5'8" × 5'8"
Load rating
H-20 opt.

2000 Gallon Septic Tank

2,000 gal
Residential

2500 Gallon Septic

2,500 gal
Commercial
Compartments
1
Dimensions
15'0" × 5'10" × 5'10"
Load rating
H-20 opt.

6000 Gallon Septic

6,000 gal
Commercial
Compartments
2
Dimensions
22'0" × 6'6" × 6'6"
Load rating
H-20

6000 Gallon Septic Tank

6,000 gal
Commercial

1000 Gallon Interceptor / Separator

1,000 gal
Interceptor
Compartments
2
Dimensions
9'2" × 5'2" × 5'6"
Load rating
H-20 opt.

1500 Gallon Interceptor / Separator

1,500 gal
Interceptor
Compartments
2
Dimensions
11'0" × 5'6" × 5'6"
Load rating
H-20 opt.

1500 Gallon Interceptor / Separator Tank

1,500 gal
Commercial Interceptor

2000 Gallon Interceptor / Separator

2,000 gal
Interceptor
Compartments
3
Dimensions
13'6" × 5'8" × 5'8"
Load rating
H-20 opt.

AdvanTex Level 2 Treatment System

Treatment
Compartments
2
Dimensions
System — varies
Load rating
H-10

Pump Station Package

Pump & dosing
Compartments
1
Dimensions
6'8" × 4'4" × 5'10"
Load rating
H-10 / H-20 opt.

No sizes match those filters

Downloads

Drawings & spec sheets

Pull the drawing you need for permitting, bidding, or install — no login, no gate.

1000 Gallon Septic — Drawing V4
1000 Gallon AdvanTex — Drawing V5
Septic sizing guide by bedrooms
Traffic-rated lid & riser options
Questions

Common questions

Straight answers from a team that has done this work for decades.

What size septic tank do I need?

As a rule of thumb: 2–3 bedrooms → 1,000 gal, 4 bedrooms → 1,250–1,500 gal, 5 bedrooms → 1,500–2,000 gal. Commercial flows are sized by design load — send us the details and we’ll spec it.

Single- or two-compartment?

Most modern installs use two compartments for better solids settling and effluent quality. Both are available, and many tanks double as effluent dosing chambers on larger systems.

Do you deliver and set the tank?

Yes. We run our own fleet of boom trucks and set tanks on grade across Montana, Northern Idaho, and Southern Alberta — no coordinating a third-party hauler for a 10,000-lb product.

Can your septic tanks be traffic-rated for drive-over?

Yes — any of our septic tanks can be built to the AASHTO HS-20 highway loading standard, with the tank and its lids reinforced to carry vehicle loads, not just the lid. Concrete, PVC, or fiberglass risers and lids are available either way. Tell us where a drive, parking area, or equipment path crosses the tank and we will spec the build. Our traffic-rated and commercial septic guide covers when you need one.

What permits do I need in Flathead County?

Every property needs a Land Research Request approval first, then county health-department review. Requirements vary by county — see the ordering steps or call us and we’ll point you to the right forms.

Talk to a real person

Talk to us about Septic & Wastewater

Tell us what you are building and we will point you to the right product, size, and lead time. No pressure, no bots.

(406) 752-7163
Contact Form

Ready when you are

Have a project in mind?

Send us the drawings, the dimensions, or just the idea. We will tell you what is possible, what it costs, and when we can set it.